Specifications
Capacity: 0.5 KVA Current Type: AC
Phase: Single Phase Type: Automatic Voltage Regulator
Display Type: Digital Display Efficiency: 0.99
Frequency: 50/60 Hz Material: Copper, PC
Protection: Overloading Protection, Undervoltage Protection, Under/Over Voltage Usage: Household
Product Name: Over And Under Voltage Protector Rated voltage: 220V/230VAC
Rated Current: 1A-63A Adjustable (default 40A) Over-Voltage Protector: 230~300V AC
Under-Voltage Protector: 140~210V AC Display: LED
Time delay for recovery: 1-600S Certificate: CE / ISO9001
Warranty: 1 Year
Product Description

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 0

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 2

230V AC Single Phase Adjustable Over and Under Voltage Protector with Over Current Protection Din rail mounting ON/OFF Switch

 

Product Description

Functions:
1.Over-voltage protection


2.Under-voltage protection


3.Over-current protection


4.Automatic recovery


5.Voltage display(voltage measurement)


6.ON/OFF Switch Control.


7. Voltage calibration: Voltage +-10% adjustable. A13


8. Restore factory settings: press the down button for more than 12s


9. Fault inquiry: Press the UP button from more than 12S


Product Parameters:
1.Model number:MEH-V-Protector


2.Power supply:230VAC 50/60Hz


3.Max.Loading power:1~40A Adjustable(default:40A); 1~63A Adjustable(default:63A)


4.Over-voltage protection value range:230V~300~OFF(default:270V):


Over-voltage recovery voltage range:225V--295V(default:250V)
Over-voltage protection action time:0.1s~30s(default value:0.5s)
Over-voltage r ecovery delay time:1s~500s(default:30s)


5.Under-voltage protection value range:140V--210V --OFF(default:170V):


Under-voltage recovery voltage range:145V--215V (default:190V)
Under-voltage protection action time:0.1s~30s(default:0.5s)
Under-voltage r ecovery delay time:1s~500s(default:30s)


6.Over-current adjustment range:1-40A (default:20A) 1-63A (default:40A):


Over-current action range:0.1~30 second (default:0.5s)
Over-current r ecovery delay time:1s~500s(default:30s)


7.Power-on delay time:1s~600s(default:10s)


8.Power consumption : <2W


9.Electric machinery life : 100,000 times


10.Installation:35mm DIN rail

 40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 4

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 6

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 8

 

Technical parameters:

 
Rated supply voltage AC 220/230V
Operation Voltage Range AC 80v~400V (1 Phase)
Rated Frequency 50/60Hz
Electric Current(>A) setting range 1~63A
Over Voltage(>U) setting range 230~300V AC
Under Voltage(<U) setting range 140~210V AC
Error 2%
>U and <U trip delay 0.5S
Reset/start delay 1s~600s
Voltage measurement accuracy 1%
Rated insulation voltage 400V
Output Contact 1NO
Protection degree IP20
Pollution degree 3
Altiude <=2000m
Operating Temperature -50°C~55°C
Humidity <=50% at 40°C
Storage Temperature -30°C~70°C

 

Default Setting:

Technical parameter Setting range Step Factory setting
Over Voltage trip value 230~300V 1V 280V
Under Voltage trip value 140~210V 1V 160V
Over Current trip value 1~63A 1A 20A
Reset/start delay 1s~600s 1s 5s

 

Current Specification 15A 25A 32A 50A 63A
Rated operating current(ln,A) 15 25 32 50 63
Maximum operating current lmax(A,Within 10 Min) 25 30 40 60 80
Max.power of load((KW) 3.6 5.5 7 11 13.9

 

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 10

 40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 12

Function  Setting & Wiring and shape dimensions:

 

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 14

 

Dimensions and installation dimensions:

 

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 16

 

Application Scenarios:

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 1840A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 20

 

 Related Products shown:

 40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 2240A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 2440A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 26

 

Certifications

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 28

 

Packaging & Shipping

 40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 30

 

Our Services

 40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 32

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 34

40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 36

 

Company Information

 40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 38

 

FAQ

 40A Din Rail Single Phase Over Under Voltage Protector Automatic Reconnect Device with On-Off Function Voltage Display SVC Use 40