Circuit Breaker with Overcurrent protection Type AC with 6A 10A 16A 20A 25A 32A 40A 2P and 4P 30mA
| BCD Curve: | B, C | Breaking Capacity: | 6 KA |
| Rated Voltage: | 230 V, 380 V | Application: | Households, Circuit-Breaking |
| Material: | Copper, High Standard Plastic Silver Copper | Mounting Type: | Rail Mounting |
| Protection: | Other | Rated Frequency (Hz): | 50 Hz |
| Type: | RCBO, Residual Current | Poles Number: | 4 |
| Product name: | Residual Current Operated RCBO | Rated current: | 10A/16A/20A/25A/32A/40A/63A |
| Rated voltage: | 230/400V | Standard: | IEC61009-1 |
| Mechanical Life: | 10000 Times | Warranty: | 2 Years |


Residual Current Operated Circuit Break with overcurrent protection 6a 10a 16a 20a 25a 32a 40a with 2P and 4P RCBO circuit breaker
YMWB8L-40 Residual Current Operated
Circuit Breaker with overcurrent protection(Electro magnetic)
Application:
The Product serves in the line of AC 50Hz,rated voltage 230V and rated current up to 40A to automatically and immediately cut off power supply once someone suffers from electric shock or leakage current above specified value.It can effectively protect personal security and avoid the damage to equipments.
The circuit-breaker can also function as overload and short-circuit protection and unfrequent changeover of line under normal condition.
The product is conformity with GB16917.1,IEC61009-1 Standards.
Feature:
1. Without auxiliary power supply,the product is designed with strong immunity and extending protection range against residual current.
2. With higher rated ultimate short circuit,up to 6KA.
3. Reliable,accurate and convenient adjustment of product instantaneous action is ensured.
4. Service life of product has been greatly enhanced through specially designed tripping mechanism.
Technical parameters:
1. Rated Current: 6A,10A,16A,20A,25A,32A,40A.
2. Rated residual operating current:0.01A,0.03A,0.1A,0.3A.
3. Tripping Characteristics: B(3ln~5ln),C(5ln~10ln)
4. According to behaviour in presence of d.c Components:Type A,Type AC.
5. Icn:6000A
6. Rated residual current operated making and breaking capacity IΔm: 500A
7. Rated residual non-operated current: IΔno: 0.5IΔn.
-----------------------------------------------------------------------------------------------------------------------------------------
YMWB8LE-40 Residual Current Operated
Circuit Breaker with overcurrent protection(Electronic)
Application:
The Product serves in the line of AC 50Hz,rated voltage 230V and rated current up to 40A to automatically and immediately cut off power supply once someone suffers from electric shock or leakage current above specified value.It can effectively protect personal security and avoid the damage to equipments.
The circuit-breaker can also function as overload and short-circuit protection and unfrequent changeover of line under normal condition.
The product is conformity with GB16917.1,IEC61009-1 Standards.
Feature:
1. With higher rated ultimate short circuit,up to 6kA.
2. Reliable,accurate and convenient adjustment of product instantaneous action is ensured.
3. Service life of product has been greatly enhanced through specially designed tripping mechanism.
Main Technical Data:
1. Rated Current: 6A,10A,16A,20A,25A,32A,40A.
2. Rated residual operating current: 0.03A,0.1A.
3. Tripping Characteristics: B,C
4. Icn:6000A
5. Rated residual current operated making and breaking capacity IΔm: 500A
6. Rated residual non-operated current: IΔno: 0.5IΔn.
| Rated Current | 6A,10A,16A,20A,25A,32A,40A |
| Rated residual operating current | 0.03A,0.1A |
| Tripping Characteristics | B(3ln~5ln),C(5ln~10ln) |
| According to behaviour in presence of d.c Components | Type A,Type AC |
| Icn | 6000A |
| Rated residual current operated making and breaking capacity IΔm | 500A |
| Rated residual non-operated current IΔno | 0.5IΔn |
2P and 4P RCBO Related Products shown: