3 Phase 4 Wire Energy Meter XTM024 Series Din Rail Smart Digital KWH Meter 3*20(80)A 380V
| Accuracy Class: | 1.0 | Measuring Energy Range: | 0-999999.9 KWh |
| Phase: | Three Phase | Dimensions: | 125*88*68mm |
| Display Type: | Digital Only | Operating Temperature: | 25℃ ~ +55℃ |
| Output Voltage: | 3X220V/380V; 3X230V/415V | Type: | DIN Rail Mounting Energy Meter |
| Usage: | Active Electric Energy Measurement | Communication: | RS485 Port MODBUS-RTU Protocol |
| Rated current: | 5(30)A/10(40)A/15(60)A/20(80 )A/30(100)A | Frequency: | 50HZ/60HZ |
| Pulse output: | 2 Channels | Starting current (A): | 0.4%Ib(In) / 0.5%Ib(In) |
| Warranty: | 2 Years | Standard: | IEC62052-11/IEC62053-21 |
| Certificate: | CE ROHS LVD EMC |


DIN RAIL TYPE KWH ENERGY METER
Application:
1. Introduction
It is a simple three phase four module Din-Rail meter with transparent meter case, which is widely used in Sub-metering system. This meter is very popular in worldwide for its novel appearance, good quality and reasonable price.
2. Features and Technical Parameters
2.1 Features:
LCD backlight display.
Inside battery to support power off display.
2.2 Technical Parameters:
- Voltage: 3*230/400V
- Current: 3*5(80)A
- Accuracy class: 1.0
- Standard: IEC62052-11, IEC62053-21
- Frequency. 50-60Hz
- Impulse constant: 800imp/kWh
- Display: LCD 6+2
- Power consumption: ≤2W, 10vA
- Starting current: 0.004lb
- Working Temperature: -20~55℃
- Storage Temperature: -25~70℃
- Working voltage: 0.9—1.1 Rated voltage
- Utmost voltage: 0.8--1.15 Rated voltage
- Average humidity value of year: ≤75%
- Creep: Less than 1 impulse when the rated voltage is 115% or current loop without current.
2.3 Startup
The meter can be started and record continuously at the reference current(see the table)
|
Meter |
Meter Class |
Power factor |
||
|
1 |
2 |
3 |
||
|
Direct connect |
0.04lb |
0.05lb |
0.01lb |
1 |
Recommended Wire(For your reference):
|
Specification(mm) |
Norminal cross section(mm2) |
Safe carrying capacity(A) |
|||
|
BX |
BLX |
BV |
BLV |
||
|
1*1.13 |
1 |
20 |
18 |
||
|
1*1.37 |
1.5 |
25 |
22 |
||
|
1*1.76 |
2.5 |
33 |
25 |
30 |
23 |
|
1*2.24 |
4 |
42 |
33 |
40 |
30 |
|
1*2.73 |
6 |
55 |
42 |
50 |
40 |
|
7*1.33 |
10 |
80 |
55 |
75 |
55 |
|
7*1.76 |
16 |
105 |
80 |
100 |
75 |
|
7*2.12 |
25 |
140 |
105 |
130 |
100 |
|
7*2.50 |
35 |
170 |
140 |
160 |
125 |
|
19*1.83 |
50 |
225 |
170 |
205 |
150 |
|
19*2.14 |
75 |
280 |
225 |
255 |
185 |
|
19*2.50 |
95 |
340 |
280 |
320 |
240 |
Note: BX(BLX) copper(Aluminum) core rubber insulated wire or BV(BLV) copper (Aluminum) core PVC plastic insulated wire, widely used in 500V or less than 500V AC and DC Power distribution system. The temperature for the data listed in the above table is 35℃,the safe capacity value for the wire on single coved.
Description:


8. Safety Instructions:
Information for Your Own Safety:
This manual does not contain all of the safety measures for operation of this equipment(module, device) because special operating conditions, local code requirements or local regulations may necessitate further measures. However, it does contain information which must be adhered to for your own personal safety and to avoid damage to the equipment. This information is highlighted by a warning triangle with an exclamation mark or a lightning bolt depending on the severity of the warning.
Warning:
Means that failure to observe the instruction can result in death, serious injury or considerable material damage.
Caution:
Means hazard of electric shock and failure to take the necessary safety precautions will result in death, serious injury or considerable material damage.
Qualified personnel:
Installation and operation of this equipment described in this manual may only be performed by qualified personal.
Only people that are authorized to install, connect and use this equipment and have the proper knowledge about labeling and grounding electrical equipment and circuits and can do so according to safety and regulatory standards are considered qualified personnel in the manual.
Use for the intend purpose:
The equipment( device, module) may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by WENZHOU MEIHENG ELECTRIC CO.,LTD
Exclusion of liability:
We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible. However, deviations from the description cannot be completely ruled out, so that no liability can be accepted for any errors or omissions in the information given. The data in this manual is checked regularly and the necessary corrections will be included in subsequent editions. If you have any suggestions, pls let us know.
Subject to technical modifications without notice.
It is prohibited to pass on or copy this document or to use or disclose its contents without our express permission. Any duplication is a violation of the law and subject to criminal and civil penalties. All rights reserved, particularly for pending or approved patents award or registered trademarks.
General Warning
After removing the packaging make sure the integrity of the unit. If in doubt don'tuse the equipment and contact technical staff.
Mounting of electric appliances must be carried out only by skilled electricians. It is imperative to observe the generally applicable safety measures.
In case of failure and /or malfunctioning of the device, turn off it. For any repair only contact technical staff. Failure to comply with the above may compromise the device safety.
DIN RAIL TYPE KWH ENERGY METER SHOWN: